| NHTSA Campaign Number: |
03V100000 |
| Vehicle/Equipment Make: |
HOME AND PARK |
| Vehicle/Equipment Model: |
ROADTREK 190 |
| Model Year: |
2003 |
| Manufacturer Campaign Number: |
2003-01 |
| Manufacturer Component Description: |
FUEL SYSTEM, GASOLINE:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS |
| Manufacturers Involved in Recall: |
HOME & PARK MOTORHOMES |
| Manufacturered: |
- |
| Type of Report: |
V (Vehicle, Equipment or Tire) |
| Potential Number of Units Affected: |
125 |
| Date Owner Notified By Manufacturer: |
20030331 |
| Recall Initiated By: |
20030331 |
| Manufacturer Responsible For Recall: |
HOME & PARK MOTORHOMES |
| Report Received Date: |
20030317 |
| Record Creation Date: |
20030321 |
| Regulation Part Number: |
|
| Federal Motor Vehicle Safety Standard Number: |
|
| Defect Summary: |
ON CERTAIN MOTOR HOMES BUILT ON CHEVROLET G-VAN CHASSIS, THE CHASSIS FUEL RETURN LINE, WHICH IS TAPPED TO SUPPLY FUEL TO THE GENERATOR, HAS BEEN FOUND TO HAVE PRESSURES THAT EXCEED THE MAXIMUM ALLOWED BY THE GENERATOR MANUFACTURER. AS A RESULT, IF THE GENERATOR IS OPERATED AT THE SAME TIME THE CHASSIS ENGINE IS RUNNING, EXCESS FUEL COULD BE DELIVERED TO THE GENERATOR, CREATING A POTENTIAL FOR A GENERATOR STALL AND POSSIBLE FUEL SPILL. |
| Consequence Summary: |
IN THE EVENT OF A FUEL SPILL, A FIRE COULD OCCUR. |
| Corrective Summary: |
DEALERS WILL INSTALL AN APPROVED KIT THAT DRAWS THE GENERATOR FUEL SUPPLY DIRECTLY FROM THE FUEL TANK. OWNER NOTIFICATION IS EXPECTED TO BEGIN DURING MARCH OR APRIL 2003. OWNERS WHO TAKE THEIR VEHICLES TO AN AUTHORIZED DEALER ON AN AGREED UPON SERVICE DATE AND DO NOT RECEIVE THE FREE REMEDY WITHIN A REASONABLE TIME SHOULD CONTACT HOME & PARK AT 1-888-762-3873. |